high-performance statistical computation. Thousands of users rely on StanBest,
for statistical modeling, data analysis, and prediction in the social,
biological, and physical sciences, engineering, and business.
Users specify log density functions in Stan’s probabilistic programming
language and get:
- full Bayesian statistical inference with MCMC sampling (NUTS, HMC)
- approximate Bayesian inference with variational inference (ADVI)
- penalized maximum likelihood estimation with optimization (L-BFGS)
Stan’s math library provides differentiable probability functions & linear
algebra (C++ autodiff). Additional R packages provide expression-based
linear modeling, posterior visualization, and leave-one-out
cross-validation.
bc,
Yes, the stability on the instrument over several days is another
systematic source of error.
Daily fluctuations in cosmic background is another. As are some very
subtle weather dependent changes in radon levels.
All good points. Still looking for the right way to extract the maximum
amount of information from the data without arbitrary choices in the
analysis.
Paul
On Wed, Sep 22, 2021 at 6:09 PM bernard cleyet <bernard@cleyet.org> wrote:
phys-l@mail.phys-l.org>
On 2021/Sep/22, at 12:16, John Denker via Phys-l <
wrote:the
We agree that "simply subtracting the background will sometimes
result in a negative number of counts".
That’s not the only problem.
If I understand correctly, if this is likely, that implies a rather small
counting rate, and, therefore, long times counting will be done; unless
half life is too short. So long background counting, but the backgroundI’ve
changes, is it diurnal? Or? Another project.
Any way; In my v. long time counting, I find sig diffs with counting
background for 200 minutes [1] separated by six and/or twelve hours.
considered counting the source and the background on two apparatuses. (~SCA
two inches of lead shielding)
As I’ve posted earlier this is “junk” collected in filters.
Also I’ve noticed that the decay of mBa-137? end in a higher background
than the back. collected before adding the elution from the Cs-137 “cow”.
This is even after several days. So I conclude the separation using the
(is it?) ion exchange resin is not perfect. Next project is to use my
to verify it’s Cs-137 “leakage”._______________________________________________
Later:
In an associated search, I find the Pasco version claims < 50 Bq/ml
leakage. I have an expensive dated calibrated Cs source, so I'll
calibrate one of my NaI detectors and verify. Maybe.
[1] The longest selected time on my The Nucleus 550 scaler-timer.
bc
_______________________________________________
Forum for Physics Educators
Phys-l@mail.phys-l.org
https://www.phys-l.org/mailman/listinfo/phys-l
Forum for Physics Educators
Phys-l@mail.phys-l.org
https://www.phys-l.org/mailman/listinfo/phys-l