Chronology Current Month Current Thread Current Date
[Year List] [Month List (current year)] [Date Index] [Thread Index] [Thread Prev] [Thread Next] [Date Prev] [Date Next]

Re: [Phys-l] Solar panel circuit



I'm using a dim witted connection to the internet and thought I'd sent this yesterday. I'll then read JD's post.

-----------------------

Ignore it -- Just use a GFI for safety -- they don't require a ground.

bc

p.s. that light lites up when the ground (green wire) is not connected to the common (white wire). It doesn't detect wether the ground is physically grounded, i.e. to the water pipe or rod stuck in the ground (earth).



(1)-------------------------- (blk)


(2)--------------------------- (white)

(4) -------------------------- (bare Cu) (green on plug)


(3)--------------------------- (blk)


2 and 4 connected at the meter box.



1=> 3 = 220 V. ; 1 = > 2 , and 3 => 2 each 110 V. White is connected to the green (bare Cu in romex) at the meter box and to a water pipe or better a big long rod stuck in the ground (earth)

I've skimmed this. It agrees w/ me.

http://www.misterfixit.com/hotnot.htm








On 2010, Jun 01, , at 21:27, scitch@verizon.net wrote:

My daughter and I just started a project and need some help. I had an
extra solar panel and inverter in the garage from a prior project. We got
the idea of hooking it up to use as a cell phone/video game/digital
camera/power tool battery charger.

I connected the solar cell (12 V 75W) to a gel cell car battery, the car
battery to an inverter, and the inverter to a power strip. The power strip
is complaining (via a red LED) that the circuit is not grounded as verified
by my GFC tester. Of course it is correct, the circuit was completely
isolated from ground.

So, I grounded the frame of the solar cell to the metal surrounding the
circuit breaker box and the negative pole of the inverter to the ground
junction on one of the garage lights. The power strip is still not happy.
Plugging the outlet tester directly into the inverter also shows that the
circuit is not grounded. Grounding the case of the inverter to the house
ac ground does not solve the problem either.

Any ideas for how to ground this thing? I don't want anybody to get hurt.
Everything works fine when plugged into the system, but that red light on
the power strip is still on.

Thanks in advance,
Mike


--------------------------------------------------------------------
mail2web - Check your email from the web at
http://link.mail2web.com/mail2web


_______________________________________________
Forum for Physics Educators