Re: transformers



On Wed, 6 Dec 2000, Larry Smith wrote:

The black box steps _up_ from the 12 VDC car battery to the 18 VDC output
the telescopes want.

Oops!


Then it's probably a switching regulator. Transformers are larger and
more expensive than inductors. Also a single value of inductor can be
used to create a wide range of stepup ratios, while a company would need
to stock many different transformers when selling a range of
transformer-based supplies. Unless you need to electrically isolate the
output from the input, your step-up supply is probably based on a switched
inductor.


((((((((((((((((((((( ( ( ( ( (O) ) ) ) ) )))))))))))))))))))))
William J. Beaty SCIENCE HOBBYIST website
billb@eskimo.com http://www.amasci.com
EE/programmer/sci-exhibits science projects, tesla, weird science
Seattle, WA 206-789-0775 freenrg-L taoshum-L vortex-L webhead-L